OP50 Sensor Bracket Press-fit:
1. Purpose: Press the sensor bracket with O-rings into the bearing; Press-fit the sensor bracket assembly and the turbine assembly;
2. Compatible Products: XK507C, JLFC3C, SP232C
3. Equipment Specifications: 800mm(W)x 1200mm(L)x2000mm(Aluminum Profile H).
4. Equipment Technical Parameters
4.1 Equipment Power: 2kw;
4.2 Air Source: ≥ 0.5Mpa oil-free, water-free clean compressed air source.
4.3 Equipment Operation Form: Product loading/unloading performed by the operator (manual), press-fitting operation completed by the equipment (automatic)
4.4 Pressing Force Monitoring: Press force of 5KN, pressure sensor accuracy 0.3%FS, equipment with self-calibration function, segmented monitoring curve.
4.5 Press-in Displacement Monitoring: Accuracy ±0.02mm, full stroke monitoring.
4.6 Qualification Judgment: Whether pressure and displacement are within the qualified range.
4.7 Position Accuracy: Coaxial alignment of the press head positioning center hole and the fixture positioning installation hole is less than 0.05mm, perpendicularity of the press head to the worktable surface is 0.05mm.
4.8 Equipment Requirements: Press head adopts a floating mechanism, ensuring rigidity at the same time; The press head and clamp feature identifiable sensors, and the equipment can automatically recognize.
34 trays.
4.9 Equipment CPK value ≥1.33; The part precision and press-fit precision are inspected according to the drawing requirements.
There are no reviews yet.